| Type 8324 is especially well suited for use in nuclear power plants and in applications with low or very high temperatures. The accelerometer utilises a compression type element to provide excellent temperature stability and a wide operational bandwidth. Type 8324 is well suited for use with permanently installed machine condition monitoring systems. Specifications: | Sensitivity: | 1,0 pC/ms-2, +/- 5% | | Type of accelerometer: | Charge | | Measuring range (peak): | 20.000 ms-2 | | Resonant frequency (typical): | 30 kHz | | Frequency Response +10%: | 1 Hz to 10 kHz | | | | Shock Limit: | 20000 ms-2 | | Sinusoidal Vibration Limit: | 10000 ms-2 | | Temperature range: | -196 to +482°C | | Mounting size: | 3 x M4 | | | |