The SM-610 Safety Monitor modules are the result of an extensive development concept that uses decades of experience and the most modern design techniques to produce a high-speed, compact data acquisition module that integrates a number of powerful features:
- DSP-based signal processing
- Up to 12 input channels (AC/DC and/or binaries)
- Up to 12 output channels plus buffered outputs
- Provides sensor power
- 10 ms module response time (typical)
- Independently operating functions
- Local logbook with date and time stamp
Front panel LED displays
- 3 for alarm relay status (alert, danger, relays latched)
- 1 for Local OK relay status
- 4 for System status (OK, TM, TO, Aux)
- Binary in/out from Communication module
- Trigger in/out
- 12 for Sensor OK status
You achieve virtual "plug ‘n play" status - with only minor on-site changes to the module configuration - and optimum adaptation to the monitoring tasks, by selecting the exact solution from the standard or application-specific SM-610 modules.
Below is a partial listing of some of the SM-610 Safety monitoring modules that are available. Please contact your Brüel & Kjær Vibro Sales Representative for a more complete listing. |

SM-610 Safety Monitor module
Back to VIBROCONTROL 6000
|
|
SM-610-xxx |
Input Channel Types |
Additional Meas. |
Output |
|
Two-point Vibr. (ISO) |
One-point Vibr. (ISO) |
Axial Pos. |
RPM |
Rod Drop |
Rel. Exp. |
Eccen. |
DC |
Binary |
Vector |
BP |
Track. BP |
DC |
Relay |
|
101
|
|
121 |
|
|
|
|
|
|
|
|
|
|
|
|
|
102
|
4 |
2 |
3 |
1 |
|
|
|
|
3 |
|
|
|
8 |
4 |
|
107
|
8 |
|
2 |
|
|
|
|
|
3 |
|
|
|
6 |
6 |
|
108
|
8 |
|
|
|
|
|
|
|
|
|
|
|
8 |
8 |
|
109
|
|
6 |
|
2 |
|
|
|
|
3 |
|
|
|
8 |
6 |
|
110
|
8 |
|
|
2 |
|
|
|
|
3 |
|
|
|
6 |
2 |
|
112
|
|
|
3 |
1 |
|
|
|
4 |
|
|
|
|
8 |
8 |
|
113
|
|
12 |
|
|
|
|
|
|
|
|
|
|
12 |
|
|
114
|
|
6 |
|
|
|
|
|
|
6 |
|
|
|
|
12 |
|
115
|
10 |
|
|
|
|
|
|
|
6 |
|
|
|
|
10 |
|
116
|
|
3 |
|
|
|
|
|
|
3 |
|
3 |
|
6 |
12 |
|
117
|
|
|
|
|
|
|
|
12 |
|
|
|
|
12 |
|
|
118
|
|
|
|
|
|
|
|
12 |
|
|
|
|
|
12 |
|
119
|
|
|
|
|
|
|
|
8 |
|
|
|
|
|
8 |
|
121
|
|
8 |
3 |
1 |
|
|
|
|
3 |
|
|
|
|
10 |
|
123
|
4 |
2 |
3 |
1 |
|
|
|
|
3 |
|
|
|
8 |
4 |
|
125
|
4 |
2 |
3 |
1 |
|
|
|
|
3 |
|
|
|
|
10 |
|
129
|
|
4 |
|
2 |
|
|
|
2 |
3 |
|
|
|
8 |
6 |
|
134
|
|
|
|
1 |
1 |
4 |
1 |
2 |
|
|
|
|
6 |
10 |
|
137
|
6 |
|
|
1 |
|
|
|
|
3 |
65 |
|
|
|
12 |
|
138
|
4 |
|
|
1 |
|
|
|
|
3 |
45 |
|
|
7 |
8 |
|
139
|
|
|
|
4 |
4 |
|
|
|
|
|
|
|
8 |
8 |
|
140
|
|
|
|
3 |
6 |
|
|
|
3 |
|
|
|
12 |
|
|
141
|
|
8 |
|
|
|
|
|
|
3 |
|
|
1 |
10 |
2 |
|
145
|
4 |
2 |
3 |
1 |
|
|
|
|
3 |
45 |
|
|
8 |
2 |
|
153
|
43 |
|
2 |
1 |
|
|
|
|
|
46 |
|
|
7 |
8 |
|
158
|
4 |
4 |
|
|
|
|
|
|
3 |
|
|
|
6 |
4 |
|
159
|
|
|
|
4 |
|
|
|
8 |
|
|
|
|
12 |
|
|
160
|
|
|
|
2 |
|
|
|
|
3 |
|
2 |
2 |
6 |
8 |
|
A02 |
Up to 84 |
Up to 84 |
Up to 24 |
2 |
|
Up to 14 |
|
2 |
3 |
Up to 44, 7 |
Up to 43 |
|
Up to 2 |
Up to 8 |
1 Accelerometers only (constant current supply)
2 SM-610-A01 has single-ended inputs. SM-610-A02 has differential inputs as the other SM-610 modules
3 The Smax/Max(X-Y) is for condition monitoring only, they are not monitored to alarm limits. The X and Y bandpass values are monitored to alarm limits
4 There is a maximum of 8 vibration inputs, but several combinations are possible (see the SM-610-A01, A02 Product Specifications)
5 All vector values (1n, 2n, Jn, Kn magnitude and phase, residual values, and overall RMS) are for condition monitoring purposes only
6 Only 1n magnitude is monitored to alarm limits, the other vector values (1n phase, 2n, Jn, Kn magnitude and phase, residual values, and overall RMS) are for condition monitoring only
7 Only 1n magnitude is monitored to alarm limits, the other vector values (1n phase, 2n magnitude and phase, residual values, and overall RMS) are for export only |